β = ≥ 2 ,
XE1203F
4.1.8 Frequency Error Indicator – FEI
When enabled this function provides an indication of the frequency error of the local oscillator compared with the
received carrier frequency. For guaranteed operation of the FEI function the following two conditions should be
met:
1) The modulation index, β , should meet the following condition:
2 ? Δ f
BR
where: Δ f = frequency deviation of the modulated input signal, BR = input data bit-rate.
2) The bandwidth of the baseband filter (BBW) must be greater than the sum of the frequency offset and the
received peak signal bandwidth, as defined below:
BBW > f OFFSET + BW SIGNAL
where BBW is the baseband filter bandwidth defined by the RTParam_BW register. f OFFSET is the difference
between the carrier frequency and the LO frequency, and BW SIGNAL is equal to ?
+ Δ f ? .
? BR
? 2
?
?
Note on the timing for FEI measurement: The timing diagram of the FEI measurement process is illustrated in
Figure 7 below. As long as the FEI function remains enabled, the frequency error is continuously measured every
2/BR seconds, starting TS_FEI (see Paragraph 3.2.2) after the FEI function is enabled. The measurement results
are loaded into the status registers Dataout_MSB_fei and Dataout_LSB_fei each time the Dataout_LSB_fei
register is read through the 3-wire serial interface. In the diagram below, Saout_fei is generated internally during a
read sequence from the “Dataout_LSB_fei ‘’ status register.
RTParam_FEI
EN
TS_FEI
2/BR
fei_out
first
evaluation
val0
val1
val2
val3
val4
0
saout_fei
Dataout_MSB_fei&
Dataout_LSB_fei
xxx
val1
val3
Figure 7: Timing diagram of the FEI measurement process
The maximum frequency of SCK during the FEI read operation is 100 kHz. When using the Konnex standard, the
bit ADParam_enable_konnex Configuration Register must be set to ‘1’.
? Semtech 2008
12
www.semtech.com
相关PDF资料
XE1205SKC868XE1 KIT STARTER FOR XE1205 868MHZ
XE1283I076TRLF IC TXRX UHF LOW POWER 72-LFBGA
XE135B LAMP GAS T3.25 XENON 13.5V .375A
XE193 LAMP GAS T-3.25 XENON 14V .33A
XE2405 LAMP GAS FILLED BI-PIN 24V 5W
XE2410 LAMP GAS FILLED BI-PIN 24V 10W
XEB09-BIS MODEM ETHERNT BRDGE MPT OUTDOOR
XK-Z11-S ZIGBEE MODULE DEVELOPMENT KIT
相关代理商/技术参数
XE1203SKC915XE2 功能描述:KIT STARTER FOR XE1203 915MHZ RoHS:否 类别:RF/IF 和 RFID >> RF 评估和开发套件,板 系列:TrueRF™ 标准包装:1 系列:- 类型:GPS 接收器 频率:1575MHz 适用于相关产品:- 已供物品:模块 其它名称:SER3796
XE1205 制造商:SEMTECH 制造商全称:Semtech Corporation 功能描述:180 MHz - 1GHz Low-Power, High Link Budget Integrated UHF Transceiver
XE1205I074TRLF 功能描述:IC TXRX 433/915MHZ 48-VQFN RoHS:是 类别:RF/IF 和 RFID >> RF 收发器 系列:- 产品培训模块:Lead (SnPb) Finish for COTS Obsolescence Mitigation Program 标准包装:30 系列:- 频率:4.9GHz ~ 5.9GHz 数据传输率 - 最大:54Mbps 调制或协议:* 应用:* 功率 - 输出:-3dBm 灵敏度:- 电源电压:2.7 V ~ 3.6 V 电流 - 接收:* 电流 - 传输:* 数据接口:PCB,表面贴装 存储容量:- 天线连接器:PCB,表面贴装 工作温度:-25°C ~ 85°C 封装/外壳:68-TQFN 裸露焊盘 包装:管件
XE1205SKC433XE1 功能描述:KIT STARTER FOR XE1205 433MHZ RoHS:否 类别:RF/IF 和 RFID >> RF 评估和开发套件,板 系列:TrueRF™ 标准包装:1 系列:- 类型:GPS 接收器 频率:1575MHz 适用于相关产品:- 已供物品:模块 其它名称:SER3796
XE1205SKC868XE1 功能描述:KIT STARTER FOR XE1205 868MHZ RoHS:否 类别:RF/IF 和 RFID >> RF 评估和开发套件,板 系列:TrueRF™ 标准包装:1 系列:- 类型:GPS 接收器 频率:1575MHz 适用于相关产品:- 已供物品:模块 其它名称:SER3796
XE1205SKC915XE1 功能描述:KIT STARTER FOR XE1205 915MHZ RoHS:否 类别:RF/IF 和 RFID >> RF 评估和开发套件,板 系列:TrueRF™ 标准包装:1 系列:- 类型:GPS 接收器 频率:1575MHz 适用于相关产品:- 已供物品:模块 其它名称:SER3796
XE1209 制造商:SEMTECH 制造商全称:Semtech Corporation 功能描述:Ultra Low Power CMOS Transceiver
XE1209C012TRLF 制造商:Semtech Corporation 功能描述: